| | ||||||
Main | News | Fixed bugs | Download | Contacts | Help | Blog | |
Order | Update | Gallery | About Us | Links | Forum | Citation | |
Fixed bugs in Chemcraft05/16/2025, b770: - We found a bug, or rather a flaw in previous versions of Chemcraft: they didn’t compute the electronic entropy when calculating the thermodynamic functions like Gibbs energy. This didn’t matter for molecules with multiplicity 1 (we checked only such molecules when comparing the results computed by Chemcraft and by other programs like Gaussian). Now we have implemented the computation of electronic entropy, and get a full match with Gaussian (and almost full match with ORCA, with some difference caused by using different algorithms for calculating the vibrational entropy); - Fixed a bug with visualization of Priroda output files with relaxed PES scan: previously, if some scan steps weren’t converged, they were not visualized by Chemcraft;
- Bugfix: in some previous versions the option “Tools/Create
animation/Trajectory animation (from multiple xyz files)” worked
improperly. In more old versions it worked properly, and that’s one more
example why we think that installing several copies of Chemcraft at one
computer is not a bad idea;
- Fixed a small bug with the option “Show MO energies
diagram” for Orca files with restricted-open computations (e.g. ROB3LYP):
previously the orbital occupied with a single electron was not marked as
alpha-occupied with only one vertical arrow; - Fixed some bugs which didn’t allow to save MDL and .sdf files for big molecules.
04/11/2025, b763: - Fixed a bug with the mass spectrum analyzer: previously it showed the graph of a peak of a fragment ion with errors, if this ion contained atoms like Be, F, Na, etc., which contain only one stable isotope. This bug didn’t harm the main feature of this tool – enumeration of possible fragment ions; - Not a bug, but an annoying problem: previous version (b762) showed by default the enantiomers in a wrong way (though this can be easily altered via “Tools/Preferences/View axes orientation”). Now we have fixed this.
03/13/2025, b762: -
Fixed a small bug of the previous version, b748: when the vibrational
frequencies were computed by Hessian, and when the normal modes were
computed, Chemcraft used the values of displacements in mass-weighted
coordinates, while in programs like Gaussian or Orca, the Cartesian
coordinates are used for this; because of that, for molecules with heavy
atoms, in the vibrational modes involving these atoms the Cartesian
displacements (amplitudes shown by the Chemcraft animator) were very big.
Probably this problem was almost unimportant for the overwhelming majority
of cases; -
Fixed a bug with visualization of TDDFT spectra from Orca5 output
files containing also spin-orbit corrected absorption spectra: the latest
version visualized such files improperly; -
In
previous version (but not in old versions) the options “save multiple XYZ
files”, “save multiple MFJ files” didn’t work; -
Fixed some very small bugs with the “Enumerate possible fragment
ions for mass spectrum” tool (not dangerous).
01/11/2024, b748: -
In previous versions, the option “Tools/Mass spectrum analysis
tools/Calculate the mass of current molecule with custom distribution of
isotopes” could work improperly for molecules containing atoms like Cl, if
you select isotopes like 37Cl: Chemcraft calculated the mass of Cl 0 for
these cases, because there is also an isotope 36Cl with zero percentage.
Probably this bug was easily revealed by the user if it occurred; -
Previous versions sometimes showed error message when reading ADF .t41 files
(but if you ignore these messages, the isosurfaces are shown correctly with
them); -
Small bug fixed: with previous versions, if you choose
“Tools/Preferences/View axes orientation”, then “Apply”, the changes
are applied only if the new settings are saved. Now this option works
properly; note that this option can be important for visualization of
enantiomers (stereoisomers); -
Fixed a bug which occurred in previous version, b726 (but not in version
b648 or earlier): with the Publication display scheme, the image was copied
to clipboard without edges on atoms or bonds. This is an example why we
recommend installing several copies of Chemcraft on one computer; -
Small bug fixed: with previous versions, sometimes the bond identification
algorithm incorrectly determined aromatic and double bonds in molecule; - Fixed some other small bugs. 09/28/2024, b726: -
Previous versions sometimes showed incorrectly the structures read from
xdatcar files (for non-cubic cells); -
With previous builds, the “Tools/Simple utilities/Calculate the energy of
a reaction” tool didn’t run on some computers (an error message was
shown); -
With previous build 688, some .xyz files with multiple structures were not
read correctly; -
Some small elaborations and bug fixes.
11/29/2023, b688: -
Fixed a problem with visualization of Quantum Espresso files which
contained lattice vectors with “non-standard” orientation (e.g. if A.y
is nonzero); -
The error “The drive cannot be found” has been fixed; - Some small elaborations and bug fixes.
07/18/2023, b654: -
Fixed a bug which prevented opening some Gaussian16 output files with
frequencies; - Fixed some small bugs.
03/01/2023, b640: -
Bug fixed - previous builds of Chemcraft stopped opening files in trial mode
after 02/2023. In the activated mode (after entering the registration key),
these builds work properly. Note that the build 635 has such problems too
(it will stop running in trial mode after 04/2023). We are sorry for the
inconvenience.
03/21/2022, b622: -
(IMPORTANT) We found and fixed a bug in previous versions with
rendering MOs from Orca output files. MOs containing F or G functions were
rendered improperly, because we did not know that Orca uses phase factors
for some AOs (e.g. F+2 orbitals are equal in Gaussian and Orca while F+3
orbitals have opposite signs in these programs). We are sorry for this
problem; -
Fixed a bug which prevented visualization of MOs from very big files; -
Fixed a bug which prevented opening of some Gaussian output files
with normal modes (where the normal mode is printed for only 1 atom in the
molecule); - Fixed some small bugs.
07/22/2021, b610: -
Fixed a bug which caused problems when visualizing TD spectrum from
large Orca output files (when the number of bands in the spectrum is bigger
than 1000); -
Fixed a bug in previous release which didn’t allow one to create
Gamess/Gaussian input file with non-standard basis sets; -
Some small elaborations. |